Machine Completely Dead Diagnostic Flow
Other PV 900 Companion Cold
Machine Completely Dead Diagnostic Flow
This flow helps determine if the machine has any power reaching it, checking everything from the facility outlet inward to the machine's main power input.
Qualified technician handoff: stop before live electrical testing, sealed-system refrigeration work, compressor service, or protected-compartment access unless a qualified technician is handling the work.
- Line voltage measured on terminal block but no low-voltage output from power supply: escalate_to_technician_advanced
- Burning smell or scorch marks detected anywhere: stop_and_disconnect_power
- Water intrusion near electrical components: stop_and_disconnect_power
- If line voltage is measured at the terminal block but no low-voltage output is present, you must escalate this to a qualified technician.
Checklist
Guided Diagnostic Steps
Work from low-risk checks toward technician-level inspection only when evidence supports it.
You can read or print the route now. The first checkbox click opens the service contact gate.
- 1
Use a known-good lamp or outlet tester to confirm the wall outlet pro...
operator-intermediatelive-voltageUse a known-good lamp or outlet tester to confirm the wall outlet provides power.
Qualified technician handoff: stop before live electrical testing, sealed-system refrigeration work, compressor service, or protected-compartment access unless a qualified technician is handling the work.
Stop conditions- If line voltage is measured at the terminal block but no low-voltage output is present, you must escalate this to a qualified technician.
- If a burning smell or scorch marks are detected anywhere, immediately stop and disconnect all power; this requires a qualified technician.
- If water intrusion is observed near electrical components, stop immediately and disconnect power; this requires a qualified technician.
Expected: Initial condition is documented before deeper diagnosis.
Evidence to note: note
- 2
Visually inspect the power cord and connections for any obvious damag...
operator-intermediatelive-voltageVisually inspect the power cord and connections for any obvious damage or signs of burning.
Qualified technician handoff: stop before live electrical testing, sealed-system refrigeration work, compressor service, or protected-compartment access unless a qualified technician is handling the work.
Stop conditions- If line voltage is measured at the terminal block but no low-voltage output is present, you must escalate this to a qualified technician.
- If a burning smell or scorch marks are detected anywhere, immediately stop and disconnect all power; this requires a qualified technician.
- If water intrusion is observed near electrical components, stop immediately and disconnect power; this requires a qualified technician.
Expected: Initial condition is documented before deeper diagnosis.
Evidence to note: note
- 3
Use a known-good lamp or outlet tester to confirm the wall outlet pro...
operator-intermediatelive-voltageUse a known-good lamp or outlet tester to confirm the wall outlet provides power.
Qualified technician handoff: stop before live electrical testing, sealed-system refrigeration work, compressor service, or protected-compartment access unless a qualified technician is handling the work.
Stop conditions- If line voltage is measured at the terminal block but no low-voltage output is present, you must escalate this to a qualified technician.
- If a burning smell or scorch marks are detected anywhere, immediately stop and disconnect all power; this requires a qualified technician.
- If water intrusion is observed near electrical components, stop immediately and disconnect power; this requires a qualified technician.
Expected: Result is documented before continuing the route.
Evidence to note: note
- 4
If the outlet does not work, the issue is facility electrical, not th...
operator-intermediatelive-voltageIf the outlet does not work, the issue is facility electrical, not the machine.
Qualified technician handoff: stop before live electrical testing, sealed-system refrigeration work, compressor service, or protected-compartment access unless a qualified technician is handling the work.
Stop conditions- If line voltage is measured at the terminal block but no low-voltage output is present, you must escalate this to a qualified technician.
- If a burning smell or scorch marks are detected anywhere, immediately stop and disconnect all power; this requires a qualified technician.
- If water intrusion is observed near electrical components, stop immediately and disconnect power; this requires a qualified technician.
Expected: Result is documented before continuing the route.
Evidence to note: note
- 5
Stop and document the machine state for technician review.
operator-intermediatelive-voltageStop and document the machine state for technician review.
Qualified technician handoff: stop before live electrical testing, sealed-system refrigeration work, compressor service, or protected-compartment access unless a qualified technician is handling the work.
Stop conditions- If line voltage is measured at the terminal block but no low-voltage output is present, you must escalate this to a qualified technician.
- If a burning smell or scorch marks are detected anywhere, immediately stop and disconnect all power; this requires a qualified technician.
- If water intrusion is observed near electrical components, stop immediately and disconnect power; this requires a qualified technician.
Expected: Result is documented before continuing the route.
Evidence to note: note
Tools for this route
Parts status
Exact public parts list not verified yet. Use this route to identify the system before ordering.
Candidate areas for part verification
Other Possible Issues
Switch routes if this symptom is not the closest match.